• STANDPIPE CONTROL VALVE SIGN (ALUMINUM SIGNS 7X10)

    $9.99
    Free Shipping!

    "STANDPIPE CONTROL VALVE" SIGN (ALUMINUM 7 X 10)

     

    Size 7 Inch x 10 Inch

    Sign Material: Aluminium

    Sign has mounting holes in each corner.

    Round Corner

    Sign Thickness 0.02''

    Sign letters color: RED

    Sign background color: WHITE

    Sign Type: Wall Mounted       

    HPD Required sign: NO (See Law and regulations)

    DOB NYC Required sign: NO (For more details see law and regulations)

    Fire Department required sign: YES (For more details see law and regulations)

    Required signs for restaurant and bars-

    DOT Required Sign: NO (See Law and regulations)

    DSNY Required Sign: NO (See Law and regulations)

         SKU: MDL NYC HMC NYC FD7-100020

    UPC: 602927406295

     Sign Group: Property Management Signs, Fire Department Signs, Hallway Signs, Control Signs, Building Signs, Standpipe Signs, Safety Signs, Equipment Signs


    This is a sturdy CONTROL VALVE FIRE DEPARTMENT SIGN - WHITE BACKGROUND WITH DARK RED LETTERS (MATERIAL IS STURDY ALUMINUM; size is 7'' x 10'') WITH ONE HOLE IN EACH CORNER. The thickness of the sign is 0.02''. This STANDPIPE CONTROL sign is required by the Fire Department and is made from a type of ALUMINUM, which is exceptionally sturdy. The sign is for both indoor and outdoor use.

    Install a VALVE CONTROL standpipe sign to stay compliant with the relevant laws, regulations and recommendations in force in NYC. Maintain the safety levels required by different federal and municipal agencies and institutions that observe and enforce the law.


    Our STANDPIPE CONTROL VALVE signage comes with four pre- drill holes, which allow you to either use screws and install sign on walls behind relevant equipment or use Jack Chain/Sturdy Wire and install sign on the equipment it refers to, in which case you can simply hang sign where it belongs.


    This is an aluminum “STANDPIPE CONTROL VALVE” SIGN with WHITE BACKGROUND,RED LETTERS,size 7x10 and 4 pre-drill holes for heavy duty installation.Post sign to locate/tag/label STANDPIPE CONTROL VALVE & inform tenant/owner/officers/Crew of its location


    This is an aluminum “STANDPIPE CONTROL VALVE” SIGN with holes for heavy duty installation. In NYC use/post sign to inform tenants/owners/guests/officers/Fire Department Crew of STANDPIPE valve CONTROLS in facility with proper HPD designation and aluminum signs


     For more Information concerning the NYC Fire Department code CLICK HERE

       

    What is a standpipe system used for?

    Automatic Dry Standpipe system is only designed to have water in the systempiping when the system is in use. Manual Dry Standpipe system are exclusively for fire department use and require a fire department pumper to supply the need pressure and water supply through a fire department connection. Standpipe systems are designed to provide fire protection water for hose lines in strategically placed locations inside a building or structure. Some older buildings only have standpipe systems while many newer buildings will have a combination system, which supplies the fire sprinkler system and the standpipe system

     

    What is the purpose of a standpipe system?

    A Standpipe is a type of rigid water piping which is built into multi-story buildings in a vertical position, to which fire hoses can be connected, allowing manual application of water to the fire. Within buildings standpipes thus serve the same purpose as fire hydrants.

     

    What is the advantage of a dry standpipe system?

    A "wet" standpipe is filled with water and is pressurized at all times. In contrast todry standpipes, which can be used only by firefighters, wet standpipes can be used by building occupants. Wet standpipes generally already come with hoses so that building occupants may fight fires quickly

     

    Are standpipes required?

    (Generally speaking, most buildings over 10,000 square feet must be fully sprinkled.) In summary, if a building is required to be equipped with a fully automatic sprinkler system, and it is more than 30 feet from surrounding grade to the highest or lowest story, a Class I standpipe system is likely required.

     

    Why is it called a standpipe?

    Standpipe may refer to: Standpipe (firefighting), a rigid vertical or horizontal pipe to which fire hoses can be connected. ... Standpipe water towers, used in the late 19th century. Standpipe (plumbing), a vertical pipe attached to a p-trap for rapid high-volume wastewater drainage such as from washing machines.

     

    How many classes of standpipe systems are there?

    The Three Types of Standpipe Systems. Class I Systems [2-1/2" (64mm) hose connections] are provided for use by fire departments and those trained in handling heavy water streams.

     

    What is a standpipe drain?

    The proper way to drain a washing machine isn't to hook the hose over the edge of a utility sink, as many homeowners do, but to install a standpipe and secure it to the wall framing. A standpipe is a vertical length of 2-inch drain pipe connected to a P-trap which is in turn connected to a drain

     

    How many basic types of standpipe systems are there?

    The specific type of system is based on the occupancy classification and building height. Standpipes have three major classifications: Class I standpipes serve a 2.5-inch fire hose connection for fire department use.

     

    What is a Class 1 standpipe?

    Class II standpipes are intended to be used by the occupants of the building, like fire extinguishers, and are equipped with a valve and 1.5-inch hose connection at each location. ... Class III standpipes are a combination of Classes I and II, using both sizes of hose connections and Class I water supply requirements.

     

    What is a standpipe valve?

    Firefighters need reliable supplies of water to effectively extinguish fires. ... Code requirements were enacted, and the use of standpipe systems – a series of pipe designed to provide water for hose lines in strategic locations within a structure – and their outlets, the fire department angle hose valve, were mandated.

     

    What is a combination standpipe?

    A combined system consists both of sprinkler piping and is a standpipe for the building. Combined systems are the usual choice by building owners and contractors because their dual purpose is sensible, safe, and economical.

     

    What is the pressure requirement & flow requirement of standpipe & sprinklers?

    The minimum pressure while flowing the required standpipe flow (500 gpm from the hydraulically most remote standpipe and 250 gpm from each additional standpipe, up to a maximum of 1000 gpm for a fully sprinklered building) shall be 75 psi at any valve outlet while flowing 250 gpm through each valve

     

    What is a standpipe test?

    A standpipe is the vertical piping that connects fire sprinkler systems and hose stations between multiple floors. It is common to see standpipes in stairwells of high-rise buildings. A rooftop standpipe test verifies the water supply, pump and piping at the topmost part of the system.

     

    How does a standpipe work?

    In North America, a standpipe is a type of rigid water piping which is built into multi-story buildings in a vertical position or bridges in a horizontal position, to which fire hoses can be connected, allowing manual application of water to the fire.

     

    Automatic Sprinkler control valve signs – These signs are designed to inform the fire department of the location and designation of the valve of the flow of water from mainline to each zone.



    Shipping and Handling Cost:

    Our Shipping is fixed whether you buy 1 item or 20 items (We ship within USA only) - do not miss this opportunity to buy all signs needed at no additional shipping cost.

     

    Sales Tax:

    We are required to collect sales tax on any product sold on this site and shipped to an address in New York. The sales tax is 8.875 percent.

     

    The requirements for sign content are determined by intended use and by applicable regulation. The BUYER is responsible for determining the appropriate content for a sign or package of signs.  HPDSigns.com makes no warranty or representation of suitability of a sign for any specific application. IT IS THE CUSTOMER'S RESPONSIBILITY TO ENSURE THAT THE SIGNS THE CUSTOMER ORDERS ARE IN COMPLIANCE WITH ALL STATE, FEDERAL, LOCAL, AND MUNICIPAL LAWS. Please review terms and conditions prior to purchase. 


    For more information about what is required, see the laws that are referenced and the rules applicable to your city and state. This page is for informational purposes only and is not intended as legal advice, professional advice or a statement of law. You may wish to consult with an attorney.


    THE OFFICIAL DOB SIGN NYC – DOBsigns.NYC will provide you with all DOB required signs, NYC Building required signs, HPD required signs and NYC Fire Department and Department of Transportation (DOT) signage. We offer a wide range of construction job site signs made mandatory by NYC building department. We are the biggest provider of building and management signs,  aluminum signs to install in buildings with proper HPD designation, Property Management Signs, required building  signs, Fire Department Signs, Hallway Signs, Control Signs, Building Signs, Standpipe Signs, Safety Signs, Equipment Signs, and HPD aluminum sign "STANDPIPE CONTROL VALVE"




    This is an aluminum “STANDPIPE CONTROL VALVE” SIGN with holes for heavy duty installation. In NYC use/post sign to inform tenants/owners/guests/officers of standpipe valve control in facility with proper HPD designation and aluminum signs