Description

Ensure Your Building's Safety: Comply with NYC's Façade Inspection & Safety Program (FISP)

As a property owner in New York City with buildings over six stories, it's your responsibility to maintain the safety and integrity of your building's exterior. The Façade Inspection & Safety Program (FISP), also known as Local Law 11, mandates regular inspections to prevent hazardous conditions.

Key Requirements:

  • Inspection Frequency: Every five years, have a Qualified Exterior Wall Inspector (QEWI)—a licensed Professional Engineer (PE) or Registered Architect (RA)—conduct a critical examination of your building's exterior walls and appurtenances.

  • Report Submission: File a technical façade report with the NYC Department of Buildings (DOB) through DOB NOW: Safety.

  • Condition Classifications:

    • Safe: No issues detected; the façade is in good condition.
    • Safe with a Repair and Maintenance Program (SWARMP): Currently safe but requires repairs or maintenance within the next five years to prevent deterioration into an unsafe condition.
    • Unsafe: Conditions that pose a hazard to public safety and require immediate attention.

Action Steps for Unsafe Conditions:

  1. Immediate Protection: Install necessary public safety measures, such as sidewalk sheds or construction fences, to protect pedestrians.

  2. Timely Repairs: Address and rectify unsafe conditions within 90 days of filing the technical report.

  3. Amended Report: Once repairs are completed, submit an amended report within two weeks to the DOB.

Consequences of Non-Compliance:

Failure to comply with FISP requirements can result in violations and significant penalties imposed by the Environmental Control Board. Ensure timely inspections, repairs, and report submissions to avoid these issues.

Stay Informed:

For detailed information, guidelines, and resources, visit the NYC Department of Buildings' Façade & Local Law webpage:

By adhering to FISP regulations, you're not only complying with the law but also ensuring the safety and well-being of all New Yorkers.

 

 

-------------------

Façade & Local Law

Façade Safety and Inspection Program (FISP)

To keep buildings safe, owners of properties higher than six stories must have exterior walls and appurtenances inspected every five (5) years – and they must file a technical façade report with the Department. See NYC Construction Codes §28-302.1 and RCNY §103-04. The current Façade Rule was last revised on November 11, 2021. See FAQs for information on 1RCNY 101-07 and 1RCNY 103-04.

Property owners must repair unsafe conditions within 90 days of filing a technical report. Once all unsafe conditions have been corrected, owners must file an amended report within two weeks.

All façade compliance filings must be submitted in DOB NOW: Safety. In DOB NOW: Safety you can:

  • Submit façade compliance filings and report unsafe façade conditions
  • Make payments
  • View and search information related to your façade filings
  • Upload documents
  • View the status of a façade filing
  • Receive emails at milestones throughout the filing process

Login to DOB NOW: Safety.

Inspection & Report Deadlines

Façade report and maintenance/repair deadlines are divided into cycles. The Department has added sub-cycles to make it easier for owners to hire qualified professionals and contractors. The last digit of a building’s block number determines if the property falls into sub-cycle A, B, or C. See Cycle 9 Sub-Cycle Diagram.

Façade Classifications

The required façade inspections are called critical examinations and may only be performed by a Qualified Exterior Wall Inspector (QEWI). Prospective QEWIs must be New York State licensed Professional Engineers (PE) or New York State Registered Architects (RA) in good standing with the New York State Education Department and New York City Department of Buildings. They must meet the qualification requirements outlined in 1 RCNY 101-07, and be approved to file façade compliance reports by the Department.. After performing an inspection, the QEWI must file an electronic technical report through DOB NOW: Safety indicating the façade’s condition and classifying the building with one of three ways:

  • Safe. A condition of a building wall, any appurtenances thereto or any part thereof not requiring repair or maintenance to sustain the structural integrity of the exterior of the building and that will not become unsafe during the next five years.

  • Safe with a repair and maintenance program (SWARMP). A condition of a building wall, any appurtenances thereto or any part thereof that is safe at the time of inspection, but requires repairs or maintenance during the next five years, but not less than one year, in order to prevent its deterioration into an unsafe condition during that five-year period.

  • Unsafe. A condition of a building wall, any appurtenances thereto, or any part thereof that is hazardous to persons or property and requires repair within one (1) year of completion of critical examinations. In addition, any condition that was reported as SWARMP in a previous report and that is not corrected at the time of the current inspection must be reported as an unsafe condition.

With an Unsafe classification, the QEWI must indicate the type and location of public protection, if required. The owner must immediately install protection, such as a sidewalk shed, construction fence, etc.

General Information

  • The technical report must be submitted by a Qualified Exterior Wall Inspector (QEWI) through, DOB NOW: Safety.
  • Owners are subject to Environmental Control Board violations and penalties if they don’t meet the deadline or fail to make timely repairs.
  • Owners with a building filed as Unsafe must request an extension if the repairs cannot be completed and an amended report cannot be filed within 104 days from the original filing date.
  • Find a DOB-approved QEWI

General Façade Report Reminders

  • Buildings with ongoing construction may not be designated as Safe.
  • Provide color photos and mapping locating each observed condition.
  • Include a statement on water-tightness.
  • Submit a certification that repairs identified in the prior cycle have been finished.
  • Cite the cause and description of the deterioration.
  • Include the QEWI’s projection of the month and year when the defects will become hazardous and cause the façade to be classified as Unsafe.
  • Cite which repairs will need a Department-issued work permit.
  • Provide details about appurtenances. Acceptable forms of public protective measures:
    • Sidewalk shed
    • Fence
    • Structural Netting

All require Department of Building permits.

DISCLAIMER
We are a small, family-owned and family-operated Brooklyn-based business. We are not a City of New York store, nor are our website, products, or services affiliated with the City of New York or any agency of the City of New York. Neither we, nor our business, websites, products, services, or any hyperlinks from our website are sponsored by, approved by, affiliated with, endorsed by, or connected to the City of New York or any agency of the City of New York, including but not limited to HPD, DOB, DOT, DSNY, FDNY, or any federal entity, directly or by implication.

DISCLAIMER ON LEGAL CODES
The codes, regulations, and requirements referenced on our website may not represent the most recent or updated versions. State, federal, or local regulatory agencies may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information provided on this site or linked from it. Customers should verify all information by reviewing the official sources directly.

DISCLAIMER ON SIGN USE
The requirements for sign content depend on intended use and applicable laws. The buyer is solely responsible for determining the appropriate content for a sign or package of signs. We make no warranty or representation regarding the suitability of any sign for a specific application. It is the customer’s responsibility to ensure that the signs ordered are in compliance with all applicable state, federal, local, and municipal laws. Customers are encouraged to carefully review our Terms and Conditions prior to purchase.

GENERAL INFORMATION DISCLAIMER
All content on this site is provided for informational purposes only and does not constitute legal advice, professional advice, or a definitive statement of law. For guidance on specific requirements, customers should consult the laws and regulations referenced, as well as any rules applicable in their jurisdiction. You may wish to consult with an attorney or qualified professional to ensure compliance with all applicable legal obligations.